0x7360 Host Computer Set Device Parameter Configuration ​

Parameter List ​

ParameterTypeRequiredDescriptionValue Range
typeintYesNumber of output (input) channels1 / 4 / 8 / 12 / 16
grouptypeintYesGroup number method0: Manual entry, 1: Global int type variable, 2: Global int type bound variable
groupintYesNumber in the group-
addtypeintYesValue storage method0: Global int type variable, 1: Global int type bound variable, 2: Global double type variable, 3: Global double type bound variable
addintYesNumber for value storage-
numintYesIndex1-10: Output, 11-20: Input
value-YesValue-
ableboolYesEnable switchtrue: enabled, false: disabled

Request Example ​

json
{
  "type": 4,
  "grouptype": 1,
  "group": 3,
  "addtype": 2,
  "add": 100,
  "num": 5,
  "value": 1,
  "able": true
}

Response ​

Controller responds and returns device parameters


0x7361 Host Computer Get Device Parameter Configuration ​

Request Parameters ​

data: None

Response ​

Controller responds and returns device parameters


0x7362 Host Computer Modify Device Parameter Configuration ​

Same as 0x7360


0x7363 Host Computer Set Connection Parameters ​

Parameter List ​

ParameterTypeRequiredDescriptionValue Range
enableboolYesConnection switchtrue: turn on connection switch, false: turn off connection switch
writenumintYesWrite length[0, 256]
readnumintYesRead length[0, 256]
scancycle-YesScan cycle-
outtimecycle-YesTimeout cycle-
networknamestringYesSelected network interface name-
writetypeintYesLocal write type0: Global bool type variable, 1: Global bool type bound variable
writeadd-YesLocal write position-
readtypeintYesLocal read type0: Global bool type variable, 1: Global bool type bound variable
readadd-YesLocal read position-

Request Example ​

json
{
  "enable": true,
  "writenum": 0,
  "readnum": 0,
  "scancycle": 0,
  "outtimecycle": 0,
  "networkname": "",
  "writetype": 0,
  "writeadd": 0,
  "readtype": 0,
  "readadd": 0
}

0x7364 Host Computer Get Connection Parameter Configuration ​

Request Parameters ​

data: None

Response ​

Controller responds and returns connection parameters


0x7365 Host Computer Modify Connection Parameters ​

Same as 0x7363


0x7366 Host Computer Get Connection Status from Controller ​

Request Parameters ​

data: None

Response ​

Controller responds and returns connection status


0x7367 Controller Returns Read Data Status ​

Controller responds and returns read data status


0x7368 Read Data Status Setting ​

Parameter List ​

ParameterTypeRequiredDescriptionValue Range
numintYesIndex information0-9: Output, 10-19: Input
value-YesValue-

Request Example ​

json
{
  "num": 2,
  "value": 1
}

0x7369 Read Data Status Setting ​

Parameter List ​

ParameterTypeRequiredDescription
stateboolYestrue: EIP settings interface parameters will change with received EIP data, false: will not change

Request Example ​

json
{
  "state": false
}